Advanced Cooling Technologies
Advanced Cooling Technologies supplies service, parts and medical chillers across North America. We built its website.
- Sector
- Industrial HVAC
- Platforms
- Web
- Built by
- BirajTech
- Find it
- Website
Advanced Cooling Technologies on screen.
Quality MRI Chiller Service & Parts
From the Advanced Cooling Technologies website, word for word advancedcoolingtech.us
Welcome to Advanced Cooling Technologies, Inc. When it comes to managing critical cooling equipment for your MRI, we've been in the business for over 20 years.
Medical Cooling Experts
When it comes to managing critical cooling equipment for your MRI, we've been in the business for over 20 years.
Trust ACT to deliver quality service, high availability chillers, and expert technical support.
Chiller Service
Emergency, Preventive Maintenance, Installation, Start Up Support. ACT has a range of service solutions.
OEM Spare Parts
We carry the full line of field replaceable parts for all Airsys Medicool Chiller models.
Chillers to Match Your MRI
Specially designed medical duty chillers for MRI applications. Choose from 10kW to 70kW models.
Technical Support
Have a question about chillers? Talk with one of our factory-trained service engineers.
Best Practices
Following the manufacturer's installation and maintenance instructions will help you get the best performance from your chiller.
Service Information
Important information for anyone servicing Airsys Medicool chillers.
Our Vision
To provide reliable, quality, and cost-efficient cooling solutions and expert service support to our valued-customers.
What Makes ACT Unique
Advanced Cooling Technologies (ACT) was started in 2004 with a vision to be the premier service, parts, and medical chiller supplier in North America. ACT has developed a reputation among Hospitals, Contractors, and Industry peers as the go-to company for medical chiller support.
ACT is a certified Women Business Enterprise and an ISO 9001:2015 company. We provide MRI Chiller Service across the USA and Canada, experienced with numerous brands of MRI chillers in use today. We pride ourselves in provding our customers with the highest level of technical product expertise and customer experience.
SERVICES TO SUPPORT YOUR MRI CHILLER
At ACT, we understand the critical nature of MRI operations. Our experience in MRI chiller installation, emergency repair and service provide our clients with peace-of-mind that their critical equipment will be managed correctly and with a sense of urgency.
Service Packages
Preventive Maintenance
- Twice-annual PM service as recommended by OEM.
- Unlimited technical support.
- Replacement parts and out of scope work to be billed separately.
Full Service
- Includes all parts and labor.
- Twice-annual PM services.
- Expedited shipping on replacement parts.
- Unlimited technical support.
Custom Service
Design an annual service package to meet your specific needs and budget.
We offer a full range of services for your MRI chiller
Chiller Maintenance
Twice annual preventive maintenance service scheduled at your convenience.
Full diagnostic reports provided to our clients.
Spare Parts
Use of quality OEM replacements parts. Expedited shipping available.
24x7 Emergency Service
24x7 service dispatch, nationwide coverage, and expert technical support.
4hr response time to most locations.
Installation
Turnkey projects including site surveys, permits, crane and installation. Plus glycol fill, start up, and remote monitoring.
Technical Support
Chiller experts well-versed in all major chiller brands.
Airsys factory-trained service engineers.
Training
Airsys certified training available. Service guides and OEM checklists ensure high quality service and reliability.
Consultation
Need help or advice on how to care for your MRI chiller?
Contact our experts at 1-800-713-1543 for a free consultation.
Quality Products, Quality Service
That's how ACT has achieved a 99% chiller availability for our clients
Easy to achieve if you follow OEM installation instructions, hire quality service teams, and have your chiller regularly serviced by factory-qualified technicians. Choose ACT for your most critical service needs.
MEDICAL CHILLER BEST PRACTICS
You made a significant investment in your MRI. You need maximum up-time from your chiller. Read these best practices for chiller installation and maintenance so you minimize costly down time on your MRI in the future.
Every other topic.
04Proper Siting and Installation
3 items
Distance:
A chiller has a maximum distance that it can be located from the MRI. Flow rate and temperature decrease the further you get away from the chiller. Distance above the MRI and below the MRI will also affect how hard the pump needs to work in order to provide the right flow needed for the MRI. Ensure that you follow the manufacturers installation instructions and recommendations, particularly for locating of the chiller. Also consider installing a city water bypass in case your chiller needs service.
AirFlow Circulation and Facing of the Condenser:
Just like any HVAC equipment, heat from the MRI is carried away by the outbound coolant and is dissipated to the environment via the chiller's condenser. If the condenser is subject to high ambient temperatures from either direct sun, other HVAC equipment blowing hot air into the fins, or insufficient air circulation around the chiller, the chiller's ability to cool your MRI is reduced. You may not notice it on a cooler day, but when it's over 125 degF on the rooftop, cooling power will be decreased. This is just the natural laws of physics.
City Water Bypass:
All chillers will require maintenance at some point. Installation of a city water bypass is highly recommended to allow your service team to work on the chiller without having to shut down the MRI. Ensure this is designed correctly with proper flow rate and drainage. Also be sure to label all valves so there are no accidental overflow/dump of coolant because of someone incorrectly opening/closing valves.
05Regular and Proper Maintenance
7 items
Any HVAC equipment needs regular maintenance to keep it operating reliably over the lifespan of the unit. Every chiller requires at least two services per year to keep it operating in top condition. It is important to check for refrigerant leaks, coolant leaks, and clean the condenser coils. Depending upon your local environment, a chiller's condenser coils may need cleaning 2 to 3 times per year. With regular maintenance, your chiller should last well past it's published end of service life.
Condenser:
Cleaning of dust and debris from the condenser coil fins is vitally important to maintain the most efficient heat rejection to the atmosphere. Air flowing over the fins pulls the heat away from the chiller. If the effective surface area is reduced due to build up of dirt film or other contaminants, the cooling power is also reduced. Ensure that the coil fins are washed in the direction opposite the air flow. You may also need to consider certain times of the year where heavy pollen is sucked into the condenser coil. Extra cleaning may be needed.
Leak check - Refrigerant and Coolant:
Fluid is the medium by which heat is transferred away from your MRI. If you lose a critical amount of either refrigerant or coolant, your MRI might not be cooled adequately. Small leaks that go unnoticed can develop into bigger problems later on. Having this checked by a qualified service technician at the regular service interval is an important step.
Compressor/Pump Loads:
How well the chiller's rotating equipment is performing can indicate future problems. To the trained technician, reading of the voltage and current from the pumps and compressors can foretell any imbalance which could lead to premature failure and costly down time.
The most important point in any chiller maintenance program is to hire an experienced and knowledgeable company who knows how to service MRI chillers. Just using an ordinary residential HVAC contractor could put you and your MRI at risk.
When to Replace Your Chiller
A chiller usually has a manufacturer recommended end of service life (EOSL). Depending upon how well a chiller is maintained, it could still work reliably to cool your MRI. Questions that should be asked in determining if you need to change your chiller are:
If your chiller is nearing EOSL, and any of these factors have negatively impacted the chiller reliability, then it may be better to replace your chiller now to avoid expensive down time in the future. Investment in a new chiller is small in comparison to the cost of major repair to your MRI or replacement of your MRI.
If you need help to evaluate your chiller's condition, please contact us at 1-800-713-1543. We will be happy to provide a recommendation over the phone with a little bit of information and history.
- Is the chiller properly cooling?
- How many service incidents has the chiller had over the past 24 months?
- Was the chiller regularly serviced at the recommended intervals, using OEM parts and following all manufacturer recommended procedures?
- Was the chiller subject to any weather extremes or repeated electrical surge events?
The Importance of Picking the Right Chiller
So why purchase a chiller designed specifically for MRI cooling?
An MRI can be a critical component in making an accurate medical diagnosis. Having an MRI chiller go down may result in the MRI itself being down. Just because a chiller has a cooling capacity that matches the MRI’s requirement, it doesn’t mean it will meet the total demand of an MRI. Look for brands such as Airsys Medicool which are designed for the service duty of MRIs.
- MRI’s are expensive pieces of equipment that need proper cooling to function well.
- MRI chillers are built with higher reliability requirements, minimizing the possibility of down time
- MRI chillers are specifically designed for the duty cycle of MRI scanning. Cooling is better controlled, and large temperature swings are eliminated.
Always Choose a Qualified Installer
Even if you have picked the right chiller, you could still face problems and lower reliability if the installation is not correctly. You need to consider all of the manufacturer siting requirements, proper ventilation, proper coolant flows, and if your service team is qualified to do the work. AIRSYS' recommendations are:
Small investments up-front, can save huge and expensive headaches down the road.
- Obtain service only from an experienced installer who knows specifically about medical cooling and MRI requirements
- Know the chiller manufacturer's specific requirements for installation - distance from MRI, elevation, air flow, etc
- Read the chiller instruction manual
- Use chillers specifically designed for MRI application
- Set up regular maintenance from service teams experienced and certified to perform service on the equipment
Need Help?
Let the experts at ACT help you navigate the world of MRI chillers. We can recommend a chiller to meet your specific needs, and maintenance plans to keep your MRI running trouble-free. Our service engineers are experts in medical cooling technologies.
FlyFare
Tell us about the problem.